JLM6L AC Molded case residual current circuit breaker (ELCB)
JLM6L series molded case circuit breaker with residual current protection, rated working voltage is up to 400V, suitable for the distribution circuit with AC 50Hz, rated working current up to 800A, as leakage protection.
Application
JLM6L series molded case circuit breaker with residual current protection, rated working voltage is up to 400V, suitable for the distribution circuit with AC 50Hz, rated working current up to 800A, as leakage protection. It can be used to prevent equipment from insulation damage, fire hazard due to ground fault. Also be used to distribute electric energy and protect circuits, power supplies and protect electrical equipment from overload, short circuit, under voltage and other faults. It can also protect motors from infrequent starting, overload and short circuit.
Technical Data
| Item | JLM6L-125 | JLM6L-250 | JLM6L-400 | JLM6L-630,800 | |
|---|---|---|---|---|---|
| Model | JLM6L-125 | JLM6L-250 | JLM6L-400 | JLM6L-630,800 | |
| Frame | 125 | 250 | 400 | 800 | |
| Poles | 2, 3, 4 | 2, 3, 4 | 3, 4 | 3, 4 | |
| Rated Current (A) | 16,20,25,32,40,50,63,80,100,125 | 125,140,160,180,200,225,250 | 225,250,315,350,400 | 400,500,630,700,800 | |
| Rated Insulation Voltage(V) | AC800 | AC800 | AC800 | AC800 | |
| Rated Working Voltage(V) | AC400 | AC400 | AC400 | AC400 | |
| Rated Impulse Withstand Voltage(V) | 8000 | 8000 | 8000 | 8000 | |
| Arcing Distance(mm) | 50 | 50 | 100 | 100 | |
| Rated Limited Short-circuit Breaking Capacity Icu(kA) | AC400V | 35 | 50 | 65 | 65 |
| Rated Working Short-circuit Breaking Capacity Ics(kA) | AC400V | 22 | 35 | 40 | 42 |
| Rated residual short circuit breaking capacity making capacity IΔm(kA) | 8.75 | 12.5 | 16.25 | 16.25 | |
| Rated residual operating current IΔn(mA) | Non-delay type | 30/100/200/300/500 | 30/100/200/300/500 | 30/100/200/300/500 | 30/100/200/300/500 |
| Delay type | 100/200/300/500 | 100/200/300/500 | 100/200/300/500 | 100/200/300/500 | |
| Rated residual non-working current.(mA) | 1/2 IΔn | 1/2 IΔn | 1/2 IΔn | 1/2 IΔn | |
| Service life(O-C) | Times/h | 60 | 60 | 60 | 60 |
| Electrical life | 8000 | 8000 | 7000 | 7000 | |
| Mechanical life | 20000 | 20000 | 10000 | 10000 | |
| Residual current breaking time | IΔn | 2 IΔn | 5 IΔn | 2 IΔn | |
| Max breaking time(s) | Non-delay | 0.2 | 0.1 | 0.04 | |
| Delay type | 0.5/1.15/2.15 | 0.35/1/2 | 0.25/0.9/1.9 | ||