CJX2- 004/ 008 4 Pole AC Contactor
CJX2-D series 4 pole AC contactors are mainly used for AC 50Hz / 60Hz.rated voltage up to 660V and rated current up to 95A for remote switch, breaking and frequent starting, controlling the AC motor.
Application
CJX2-D series 4 pole AC contactors are mainly used for AC 50Hz / 60Hz.rated voltage up to 660V and rated current up to 95A for remote switch, breaking and frequent starting, controlling the AC motor. Moreover, the contactor can act as the time-delay contactor, reversible contactor, star-delta starter by the accessories addition such as addition of modular auxiliary contact set. Air time delay head, mechanical interlock mechanism, etc. Moreover,it could act as the electromagnetic starter by the direct plug of the thermal relay. This product conforms to the requirement of IEC60947-4-1& GB14048.4 standards.
004: Represents 4 NO main contacts
008: Represents 2 NO 2NC main contacts
Standard Control Circuit Voltages
| Volts | 24 | 42 | 48 | 110 | 220/230 | 230 | 240 |
|---|---|---|---|---|---|---|---|
| 50Hz | B5 | D5 | E5 | F5 | M5 | P5 | U5 |
| 60Hz | B6 | D6 | E6 | F6 | M6 | - | U6 |
| 50/60Hz | B7 | D7 | E7 | F7 | M7 | P7 | U7 |
| Volts | 380/400 | 400 | 415 | 440 | 500 | 660 |
|---|---|---|---|---|---|---|
| 50Hz | Q5 | V5 | N5 | R5 | S5 | Y5 |
| 60Hz | Q6 | - | - | R6 | - | - |
| 50/60Hz | Q7 | V7 | N7 | R7 | - | - |
Specifications
| Item | CJX2-D09 | CJX2-D12 | CJX2-D18 | CJX2-D25 | CJX2-D32 | CJX2-D40 | CJX2-D50 | CJX2-D65 | CJX2-D80 | CJX2-D95 |
|---|---|---|---|---|---|---|---|---|---|---|
| Rated working current (A) AC-3 | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
| Rated working current (A) AC-4 | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 44 |
| AC-3 capacity of 3 phase
|
2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
| AC-3 capacity of 3 phase
|
4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 |
| AC-3 capacity of 3 phase
|
4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | 45 | 45 |
| AC-3 capacity of 3 phase
|
5.5 | 7.5 | 10 | 15 | 18.5 | 22 | 30 | 37 | 55 | 55 |
| AC-3 capacity of 3 phase
|
5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 55 |
| Rated heat current (A) | 20 | 20 | 32 | 40 | 50 | 60 | 80 | 80 | 125 | 125 |
| AC-4×10⁴ | 100 | 100 | 100 | 100 | 80 | 80 | 60 | 60 | 60 | 60 |
| AC-3×10⁴ | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | 10 | 10 |
| Mechanical life×10⁴ | 1000 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | 600 | 600 |
| Number of the contact | 4NO/2NO 2NC | 4NO/2NO 2NC | 4NO/2NO 2NC | 4NO/2NO 2NC | 4NO/2NO 2NC | 4NO/2NO 2NC | 4NO/2NO 2NC | 4NO/2NO 2NC | 4NO/2NO 2NC | 4NO/2NO 2NC |