JLB67RN‑125 Series residual current circuit breaker is used for protection against electrical leakage, overload, short circuit, over voltage in the circuit of 50/60Hz,rated voltage 230/400V, rated current up to 125A.When people come across the electric shock or the leakage current of the electrical network exceeds the fixed value.

Application

JLB67RN‑125 Series residual current circuit breaker is used for protection against electrical leakage, overload, short circuit, over voltage in the circuit of 50/60Hz,rated voltage 230/400V, rated current up to 125A.When people come across the electric shock or the leakage current of the electrical network exceeds the fixed value.This product can cut off the fault current in one second so as to protect personal safety and prevent accident on equipments caused by residual current from happening.It also can be used to protect circuit against short circuit and overloading,and used for infrequent on‑and‑off switching operation under the normal circumstance.lt is mainly applied in architectural lighting and power distribution system protection.

• This product meet the standard of IEC/EN60947‑2 & IEC/EN61009‑1
• Maximum connecting ability of 35mm² ,wiring torque 3.5Nm, applicable to a variety of installing equipments.wiring stronger.
• Protection class:IP20

Technical Data

Item     IEC/EN 60947-2 IEC/EN 61009-1
Electrical features Standard   IEC/EN 60947-2 IEC/EN 61009-1
Poles   1P N, 2P, 3P, 3P N, 4P  
Rated current In A 63, 80, 100, 125  
Rated voltage Ue V 230/400  
Insulation voltage Ui V 400  
Rated frequency Hz 50/60  
Rated sensitivity IΔn A 0.03, 0.1, 0.3  
Rated residual making and breaking capacity IΔm A Icu=6000 Ics=6000
Break time under IΔn S 0.1  
Rated impulse withstand voltage (1.2/50) Uimp V 6000  
Dielectric test voltage at and ind.Freq.for 1 min kV 2.5  
Pollution degree   2  
Electrical life and Mechanical life   4000  
Mechanical features Thermo-magnetic release characteristic   8–12 In C
Fault current indicator ℃ Yes  
Protection degree ℃ IP20  
Ambient temperature(with daily average≤35℃) ℃ -5~ 40  
Storage temperature ℃ -25~ 70  
Combination with accessories Terminal connection type   Cable/U-type busbar/Pin-type busbar  
Terminal size top/bottom for cable
 
AWG
mm²
 
AWG
25 18-3  
Tightening torque mounting
 
In-lbs.
N·m 2.5 22 On DIN rail EN 60715 (35mm) by means of fast clip device  
Connection   From top and bottom  